Contact Information
  • Telephone:0086-17183463881
  • wechat:0086-17183463881
  • Email:admin@longcaremed.com
Monday To Friday 8:00 - 20:00
WECHAT CODE
WECHAT CODE

RSL81 Rotating Anode X-ray Tube Assembly for Medical Diagnosis

Intended for use in computed tomography (CT) equipment for emitting X-rays for medical diagnosis. This X-ray tube assembly is composed of housing, tube insert, stator and insulation oil.

  • Product Details
  • RSL81 is an X-ray tube assembly with a 140 mm diameter target plate and 5.0 MHU heat content. This product is used as an X-ray radioactive source for computed tomography (CT) equipment in medical and physical examination institutions.
    This X-ray tube assembly is composed of housing, tube insert, stator and insulation oil.
    Intended for use in computed tomography (CT) equipment for emitting X-rays for medical diagnosis.


    Specifications:

    Nominal X-ray Tube Voltage 140kV
    Nominal CT Anode Input Power 45kW
    Nominal Continuous Input Power 3.5kW
    Nominal Focal Spot Value (YY/T 0063) 0.8 x 0.7
    Target Angle 7°
    Target Material TZM based W-Re Alloy Target
    Cooling Medium Insulation oil
    Weight 48.2 kg ± 0.2 kg
    Power supply 1) Operating voltage of high-voltage generator: d.c. 140 kV ±7 kV 2) The power capacity > 45 kW
    Transportation and Storage Ambient temperature -20 ºC ~ +55 ºC, Relative humidity10 % ~ 93 %,Atmospheric pressure 700 hPa ~ 1060 hPaIn a well-ventilated warehouse with no corrosive substances.
    Environmental Conditions Ambient temperature: +10 ºC ~ +40 ºC,Relative humidity: 30 % ~ 75 %, Atmospheric pressure: 700 hPa ~ 1060 hPa


    RSL81 is an X-ray tube assembly with a 140 mm diameter target plate and 5.0 MHU heat content. This product is used as an X-ray radioactive source for computed tomography (CT) equipment in medical and physical examination institutions.
    This X-ray tube assembly is composed of housing, tube insert, stator and insulation oil.
    Intended for use in computed tomography (CT) equipment for emitting X-rays for medical diagnosis.


    Specifications:

    Nominal X-ray Tube Voltage 140kV
    Nominal CT Anode Input Power 45kW
    Nominal Continuous Input Power 3.5kW
    Nominal Focal Spot Value (YY/T 0063) 0.8 x 0.7
    Target Angle 7°
    Target Material TZM based W-Re Alloy Target
    Cooling Medium Insulation oil
    Weight 48.2 kg ± 0.2 kg
    Power supply 1) Operating voltage of high-voltage generator: d.c. 140 kV ±7 kV 2) The power capacity > 45 kW
    Transportation and Storage Ambient temperature -20 ºC ~ +55 ºC, Relative humidity10 % ~ 93 %,Atmospheric pressure 700 hPa ~ 1060 hPaIn a well-ventilated warehouse with no corrosive substances.
    Environmental Conditions Ambient temperature: +10 ºC ~ +40 ºC,Relative humidity: 30 % ~ 75 %, Atmospheric pressure: 700 hPa ~ 1060 hPa