Features:
1.500 mA Digital X-Ray Radiography Machine is mainly used for medical examinations of human breasts, limbs, pelvis and lumbar vertebrae.
2. HF &HV-Generator controlled by microcomputer, the exposure conditions are stable and accurate, and the rotation angle is accurate, which meets the needs of clinical multi-position photography.
3. Operation interface liquid crystal display, simple and convenient position information and exposure parameter setting, angle of the boring arm bracket, display of position information.
4. The tube capacity protection and fault self-diagnosis can be displayed in code form for convenient use and maintenance.
Detail Specification:
X-ray Tube:
1.X-ray tube model XD52-30.5/125KV/XD52-10.40/150KV
2. Focus: Double focus 1×1, 2×2
3. The rated speed of the anode is 2800r/min.
Multifunctional Radiology table:
1. Table surface movement: electromagnetic lock pedal release. Vertical: ±560m. Horizontal: ±120mm.
2. Fixed X-ray grid: Line: 40L/cm, Grid Ratio: 10:1, F.D: 2500px. Movement range: ≥ 610mm.
3. Radiography specifications:5" x 7", 8" x 10", 10" x 12", 11" x 14", 12" x 15", 14" x 14", 14" x 17"
4. Table surface to film distance: 75mm.
5. Table height: 700mm.
6. Column movement: 180° every 90° positioning, longitudinal stroke ≥1500mm.
7. Column movement: 180° every 90° positioning, longitudinal stroke ≥1500mm.
X ray collimator:
Max irradiation field: SID (FFD) = 1000mm hours, no less than 430 mm x 430 mm
Min irradiation field: 0x0 mm
Inherent filter: 1 mm·Al/75kVp
Additional filter: 1 mm·Al and 2 mm·Al
Lead leaf control mode: manual
Working power: 24V AC/DC, 150 W (The lowest safe voltage)
HV-Generator:
Voltage: 380V±10%
Frequency: 50HZ±1HZ
Resistance: ≤0.3Ω
Inverting Frequency: ≥30kHZ
Power: ≥50kW
Tube Current: 16-500mA, Steps are adjustable
Tube Voltage: 45-125KV, Stepping is 1KV
Exposure Time: 0.01-6.3S,26 steps
Selection Mode: 64 kinds of exposure conditions are stored, the operator can choose them freely
APR storage capacity: 2400 data
Can Equip with Flat Panel Detector upgrade to DR system:
14”×17” Cassette flat panel detector
Scintillator: CSI Direct Growth
Imaging Area: 433.7 x 354.8 mm2,
Pixels Array: 2816X2304,
Pixel Size: 154 μm,
Grey Scale: 16 bits,
Communication Interface: GbitE,
Image Acquisition Time: 2-3s
Dimension: 460x384x15mm3
Weight: 3.0Kg
Features:
1.500 mA Digital X-Ray Radiography Machine is mainly used for medical examinations of human breasts, limbs, pelvis and lumbar vertebrae.
2. HF &HV-Generator controlled by microcomputer, the exposure conditions are stable and accurate, and the rotation angle is accurate, which meets the needs of clinical multi-position photography.
3. Operation interface liquid crystal display, simple and convenient position information and exposure parameter setting, angle of the boring arm bracket, display of position information.
4. The tube capacity protection and fault self-diagnosis can be displayed in code form for convenient use and maintenance.
Detail Specification:
X-ray Tube:
1.X-ray tube model XD52-30.5/125KV/XD52-10.40/150KV
2. Focus: Double focus 1×1, 2×2
3. The rated speed of the anode is 2800r/min.
Multifunctional Radiology table:
1. Table surface movement: electromagnetic lock pedal release. Vertical: ±560m. Horizontal: ±120mm.
2. Fixed X-ray grid: Line: 40L/cm, Grid Ratio: 10:1, F.D: 2500px. Movement range: ≥ 610mm.
3. Radiography specifications:5" x 7", 8" x 10", 10" x 12", 11" x 14", 12" x 15", 14" x 14", 14" x 17"
4. Table surface to film distance: 75mm.
5. Table height: 700mm.
6. Column movement: 180° every 90° positioning, longitudinal stroke ≥1500mm.
7. Column movement: 180° every 90° positioning, longitudinal stroke ≥1500mm.
X ray collimator:
Max irradiation field: SID (FFD) = 1000mm hours, no less than 430 mm x 430 mm
Min irradiation field: 0x0 mm
Inherent filter: 1 mm·Al/75kVp
Additional filter: 1 mm·Al and 2 mm·Al
Lead leaf control mode: manual
Working power: 24V AC/DC, 150 W (The lowest safe voltage)
HV-Generator:
Voltage: 380V±10%
Frequency: 50HZ±1HZ
Resistance: ≤0.3Ω
Inverting Frequency: ≥30kHZ
Power: ≥50kW
Tube Current: 16-500mA, Steps are adjustable
Tube Voltage: 45-125KV, Stepping is 1KV
Exposure Time: 0.01-6.3S,26 steps
Selection Mode: 64 kinds of exposure conditions are stored, the operator can choose them freely
APR storage capacity: 2400 data
Can Equip with Flat Panel Detector upgrade to DR system:
14”×17” Cassette flat panel detector
Scintillator: CSI Direct Growth
Imaging Area: 433.7 x 354.8 mm2,
Pixels Array: 2816X2304,
Pixel Size: 154 μm,
Grey Scale: 16 bits,
Communication Interface: GbitE,
Image Acquisition Time: 2-3s
Dimension: 460x384x15mm3
Weight: 3.0Kg