Contact Information
    Contact Information
  • Telephone:0086-17183463881
  • Wechat:0086-17183463881
  • Mailbox:admin@longcaremed.com
Monday To Friday 8:00 - 20:00
WECHAT CODE
WECHAT CODE

YH-500RPDR HF Radiography Vet X-ray Machine

  • Product Details
  • Features

    1.500 mA Digital X-Ray Radiography Machine is mainly used for medical examinations of human breasts, limbs, pelvis and lumbar vertebrae.

    2. HF &HV-Generator controlled by microcomputer, the exposure conditions are stable and accurate, and the rotation angle is accurate, which meets the needs of clinical multi-position photography.

    3. Operation interface liquid crystal display, simple and convenient position information and exposure parameter setting, angle of the boring arm bracket, display of position information.

    4. The tube capacity protection and fault self-diagnosis can be displayed in code form for convenient use and maintenance.

     

    Detail Specification

    X-ray Tube

    1.X-ray tube model XD52-30.5/125KV/XD52-10.40/150KV

    2. Focus: Double focus 1×1, 2×2

    3. The rated speed of the anode is 2800r/min.

     

    Multifunctional Radiology table

    1. Table surface movement: electromagnetic lock pedal release. Vertical: ±560m. Horizontal: ±120mm.

    2. Fixed X-ray grid: Line: 40L/cm, Grid Ratio: 10:1, F.D: 2500px. Movement range:  610mm.

    3. Radiography specifications:5" x 7", 8" x 10", 10" x 12", 11" x 14", 12" x 15", 14" x 14", 14" x 17"

    4. Table surface to film distance: 75mm.

    5. Table height: 700mm.

    6. Column movement: 180° every 90° positioning, longitudinal stroke 1500mm.

    7. Column movement: 180° every 90° positioning, longitudinal stroke 1500mm.

     

    X ray collimator

    Max irradiation field: SID (FFD) = 1000mm hours, no less than 430 mm x 430 mm

    Min irradiation field: 0x0 mm

    Inherent filter: 1 mm·Al/75kVp

    Additional filter: 1 mm·Al and 2 mm·Al

    Lead leaf control mode: manual

    Working power: 24V AC/DC, 150 W (The lowest safe voltage)

     

    HV-Generator

    Voltage: 380V±10%

    Frequency: 50HZ±1HZ

    Resistance: 0.3Ω

    Inverting Frequency: 30kHZ

    Power: 50kW

    Tube Current: 16-500mA, Steps are adjustable

    Tube Voltage: 45-125KV, Stepping is 1KV

    Exposure Time: 0.01-6.3S26 steps

    Selection Mode: 64 kinds of exposure conditions are stored, the operator can choose them freely

    APR storage capacity: 2400 data

     

    Can Equip with Flat Panel Detector upgrade to DR system

    14”×17 Cassette flat panel detector

    Scintillator: CSI Direct Growth

    Imaging Area: 433.7 x 354.8 mm2

    Pixels Array: 2816X2304

    Pixel Size: 154 μm

    Grey Scale: 16 bits

    Communication Interface: GbitE

    Image Acquisition Time: 2-3s

    Dimension: 460x384x15mm3

    Weight: 3.0Kg


    Features

    1.500 mA Digital X-Ray Radiography Machine is mainly used for medical examinations of human breasts, limbs, pelvis and lumbar vertebrae.

    2. HF &HV-Generator controlled by microcomputer, the exposure conditions are stable and accurate, and the rotation angle is accurate, which meets the needs of clinical multi-position photography.

    3. Operation interface liquid crystal display, simple and convenient position information and exposure parameter setting, angle of the boring arm bracket, display of position information.

    4. The tube capacity protection and fault self-diagnosis can be displayed in code form for convenient use and maintenance.

     

    Detail Specification

    X-ray Tube

    1.X-ray tube model XD52-30.5/125KV/XD52-10.40/150KV

    2. Focus: Double focus 1×1, 2×2

    3. The rated speed of the anode is 2800r/min.

     

    Multifunctional Radiology table

    1. Table surface movement: electromagnetic lock pedal release. Vertical: ±560m. Horizontal: ±120mm.

    2. Fixed X-ray grid: Line: 40L/cm, Grid Ratio: 10:1, F.D: 2500px. Movement range:  610mm.

    3. Radiography specifications:5" x 7", 8" x 10", 10" x 12", 11" x 14", 12" x 15", 14" x 14", 14" x 17"

    4. Table surface to film distance: 75mm.

    5. Table height: 700mm.

    6. Column movement: 180° every 90° positioning, longitudinal stroke 1500mm.

    7. Column movement: 180° every 90° positioning, longitudinal stroke 1500mm.

     

    X ray collimator

    Max irradiation field: SID (FFD) = 1000mm hours, no less than 430 mm x 430 mm

    Min irradiation field: 0x0 mm

    Inherent filter: 1 mm·Al/75kVp

    Additional filter: 1 mm·Al and 2 mm·Al

    Lead leaf control mode: manual

    Working power: 24V AC/DC, 150 W (The lowest safe voltage)

     

    HV-Generator

    Voltage: 380V±10%

    Frequency: 50HZ±1HZ

    Resistance: 0.3Ω

    Inverting Frequency: 30kHZ

    Power: 50kW

    Tube Current: 16-500mA, Steps are adjustable

    Tube Voltage: 45-125KV, Stepping is 1KV

    Exposure Time: 0.01-6.3S26 steps

    Selection Mode: 64 kinds of exposure conditions are stored, the operator can choose them freely

    APR storage capacity: 2400 data

     

    Can Equip with Flat Panel Detector upgrade to DR system

    14”×17 Cassette flat panel detector

    Scintillator: CSI Direct Growth

    Imaging Area: 433.7 x 354.8 mm2

    Pixels Array: 2816X2304

    Pixel Size: 154 μm

    Grey Scale: 16 bits

    Communication Interface: GbitE

    Image Acquisition Time: 2-3s

    Dimension: 460x384x15mm3

    Weight: 3.0Kg